MSZ EN IEC 61010-2-101:2023
Dokumentumazonosító
181264
Cím
Villamos mérő-, szabályozó- és laboratóriumi készülékek biztonsági előírásai. 2-101. rész: In vitro diagnosztikai (IVD) gyógyászati készülékek biztonsági követelményei (IEC 61010-2-101:2018)
Angol cím
Safety requirements for electrical equipment for measurement, control, and laboratory use. Part 2-101: Safety requirements for in vitro diagnostic (IVD) medical equipment (IEC 61010-2-101:2018)
Alkalmazási terület
This clause of Part 1 is applicable except as follows: 1.1.1 Equipment included in scope Replacement: Replace the text, except the first paragraph, with the following new text: This part of IEC 61010 applies to equipment intended for in vitro diagnostic (IVD) medical purposes, including self-test IVD medical purposes. IVD medical equipment, whether used alone or in combination, is intended by the manufacturer to be used in vitro for the examination of specimens, including blood and tissue samples, derived from the human body, solely or principally for the purpose of providing information concerning one or more of the following: - a physiological or pathological state; or - a congenital abnormality; - the determination of safety and compatibility with potential recipients; - the monitoring of therapeutic measures. Self-test IVD medical equipment is intended by the manufacturer for use by lay persons in a home environment. NOTE If all or part of the equipment falls within the scope of one or more other Part 2 standards of the IEC 61010 series as well as within the scope of this document, consideration is given to those other Part 2 standards. 1.1.2 Equipment excluded from scope Addition: Add the following new item: aa) equipment within the scope of IEC 61010-2-081 unless it is specifically intended by the manufacturer to be used for in vitro diagnostic examination. 1.2 Object 1.2.1 Aspects included in scope Addition: Add the following two new items: aa) biohazards; bb) hazardous chemical substances. 1.2.2 Aspects excluded from scope Addition: Add the following new item and note: aa) the handling or manipulation outside the equipment of material under analysis. NOTE Requirements covering these subjects are the responsibility of committees preparing the relevant standards.
ICS
11.040.55 Diagnosztikai készülékek
19.080 Villamos és elektronikus vizsgálat
A szabvány nyelve
angol
Az érvényesség kezdete
2023-04-01
További adatok
Forrás
idt IEC 61010-2-101:2018; idt EN IEC 61010-2-101:2022
Utód
Kiegészítő információk
SZK-közlemények
Kapcsolódó európai jogszabály
Kereskedelmi adatok
A szabvány
kapható formátuma
Papír ,
PDF (letöltés) (a fájl mérete: 522082) ,
oldalszáma
20 oldal; K kategória