Szabványkereső

Hivatkozási szám, azonosító jelzet, vagy a szabványcímben előforduló kulcsszó szerinti keresés:


ICS (a szabványok nemzetközi osztályozási rendszere) szerinti keresés

Nettó ár: 21330 Ft
Az online rendelés jelenleg nem elérhető.
Alapadatok
Hivatkozási szám
MSZ EN IEC 62682:2023
Dokumentumazonosító
181549
Cím
Riasztórendszerek kezelése a feldolgozóiparban (IEC 62682:2022)
Angol cím
Management of alarm systems for the process industries (IEC 62682:2022)
Alkalmazási terület
1.1 General applicability This document specifies general principles and processes for the management of alarm systems based on controls system and human-machine interfaces (HMI) for facilities in the process industries. It covers all alarms to be presented to the operator through the control system, which includes alarms from basic process control systems, annunciators, packaged systems, and safety instrumented systems. The practices in this document are applicable to continuous, batch, and discrete processes. There can be differences in implementation to meet the specific needs based on process type. The primary function within the alarm system is to notify operators of abnormal process conditions or equipment malfunctions and support the response. The alarm systems can include both the basic process control system (BPCS) and the safety instrumented system (SIS), each of which uses measurements of process conditions and logic to generate alarms. Figure 1 illustrates the concepts of alarm and response dataflow through the alarm system. The alarm system also includes a mechanism for communicating the alarm information to the operator via an HMI, usually a computer screen or an annunciator. Additional functions of the alarm system are an alarm and event log, an alarm historian, and the generation of performance metrics for the alarm system. There are external systems that can use the data from the alarm system. Figure 1 is not intended to represent physical wiring. Ábra 1.2 Exclusions and inclusions 1.2.1 Operators The functions of the operator receiving and responding to alarms are included in the scope of this document. Management of operators is excluded from the scope of this document. 1.2.2 Process sensors and final control elements The alarms implemented in sensors and final control elements are included in the scope of this document. The design and management of process sensors and final control elements are excluded from the scope of this document. 1.2.3 Annunciators The integration of annunciators into an alarm system is included in the scope of this document. The specification and design of annunciators is excluded from the scope of this document. 1.2.4 Human machine interface The appearance of alarms in the HMI and functions of alarm related displays are included in the scope of this document. The design and maintenance of the HMI are excluded from this document. NOTE ANSI/ISA-101.01-2015 provides information on HMI design and maintenance. 1.2.5 Safety instrumented systems The alarms implemented in a safety instrumented system are included in the scope of this document. The design and management of safety instrumented systems are excluded from this document. NOTE IEC 61511-1 provides information on safety instrumented systems. 1.2.6 Fire and gas detection and protective systems The alarms from fire and gas detection and protective systems presented to the operator through the control system are included in the scope of this document. The design and management of fire and gas detection and protective systems is excluded from the scope of this document. 1.2.7 Security systems The alarms from security systems presented to the operator through the control system are included in the scope of this document. The design and management of security systems is excluded from the scope of this document. 1.2.8 Packaged systems The alarms from packaged systems presented to the operator through the control system are included in the scope of this document. The design and management of packaged systems is excluded from the scope of this document. 1.2.9 Event data The indication and processing of analog, discrete, and event data other than alarm indications are excluded from the scope of this document. The analysis techniques using both alarm and event data are excluded from the scope of this document. 1.2.10 Alarm identification methods Required methods of alarm identification are not specified in this document. Examples of alarm identification methods are listed. 1.2.11 Management of change A specific management of change (MOC) procedure is not included in this document. Some requirements and recommendations for an MOC procedure are included. 1.2.12 Purchase specification This document is not intended to be used as an alarm system purchase specification.
ICS
13.320 Vészjelző és figyelmeztetőrendszerek
25.040.40 Ipari folyamatok mérése és vezérlése
A szabvány nyelve
angol
Az érvényesség kezdete
2023-05-01
További adatok
Forrás
idt IEC 62682:2022; idt EN IEC 62682:2023
Utód
Módosítás
SZK-közlemények
Kapcsolódó európai jogszabály
Kereskedelmi adatok
A szabvány
kapható formátuma
Papír ,
PDF (letöltés) (a fájl mérete: 1906020) ,
oldalszáma
85 oldal; X kategória
ára
Nettó: 21330 Ft
Bruttó:
Papír formátum esetén (5% Áfával): 26876 Ft
PDF (letöltés) formátum esetén (27% Áfával): 27089 Ft
Szabvány életútja
Megtekintett szabvány

MSZ EN IEC 62682:2023

2023-05-01

Utódok

Jelenleg nincsenek utódok