Alapadatok
Hivatkozási szám
MSZ EN 62353:2008
Dokumentumazonosító
645523
Cím
Gyógyászati villamos készülékek. Gyógyászati villamos készülékek ismétlődő és javítás utáni vizsgálata (IEC 62353:2007)
Angol cím
Medical electrical equipment. Recurrent test and test after repair of medical electrical equipment (IEC 62353:2007)
Alkalmazási terület
This International Standard applies to testing of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS, or parts of such equipment or systems, which comply with IEC 60601 1, before PUTTING INTO SERVICE, during MAINTENANCE, INSPECTION, SERVICING and after REPAIR or on occasion of RECURRENT TESTS to assess the safety of such ME EQUIPMENT or ME SYSTEMS or parts thereof. For equipment not built to IEC 60601-1 these requirements may be used taking into account the safety standards for the design and information in the instructions for use of that equipment. This standard contains tables with allowable values relating to different editions of IEC 60601-1. For the purpose of this standard, the application of measuring methods is independent of the edition according to which the ME EQUIPMENT OR ME SYSTEM is designed. This standard contains: – "general requirements", which contain clauses of general concern, and – "particular requirements", further clauses handling special types of ME EQUIPMENT or ME SYSTEMS and applying in connection with the "General requirements". NOTE 1 At this stage, there are no particular requirements. This standard is not suitable to assess whether ME EQUIPMENT or ME SYSTEMS or any other equipment comply with the relevant standards for their design. This standard does not define requirements for REPAIR, exchange of components and MODIFICATION of ME EQUIPMENT or ME SYSTEMS. NOTE 2 All MAINTENANCE, INSPECTION, SERVICING, and REPAIR done in accordance with MANUFACTURER's instructions maintain the conformity to the standard used for the design of the equipment. Otherwise conformity to applicable requirements have to be assessed and verified. This standard is also applicable to tests after REPAIR. The testing shall be defined according to the extent of work performed and applicable guidance from the MANUFACTURER. This standard is not intended to define time intervals for RECURRENT TESTS. If such intervals are not defined by the MANUFACTURER, Annex F may be used to help establish such intervals.
ICS
11.040.01 Orvostechnikai berendezések általában
A szabvány nyelve
angol
Az érvényesség kezdete
2008-06-01
A visszavonás napja
2017-10-09
További adatok
Forrás
idt EN 62353:2008; idt IEC 62353:2007
Előd
Módosítás
SZK-közlemények
Kapcsolódó európai jogszabály
Kereskedelmi adatok
A szabvány
kapható formátuma
Papír ,
PDF (letöltés) (a fájl mérete: 752067) ,
oldalszáma
54 oldal; U kategória
ára
Nettó: 17420 Ft
Bruttó:
Papír formátum esetén (5% Áfával): 21949 Ft
PDF (letöltés) formátum esetén (27% Áfával): 22123 Ft
Szabvány életútja
Elődök

Jelenleg nincsenek előzmények

Megtekintett szabvány

MSZ EN 62353:2008

2008-06-01 - 2017-10-09