Hivatkozási szám
MSZ EN 61010-031:2015
Dokumentumazonosító
161989
Cím
Villamos mérő-, szabályozó- és laboratóriumi készülékek biztonsági előírásai. 031. rész: Villamos mérési és vizsgálati célú kézi mérőszondák biztonsági előírásai (IEC 61010-031:2015)
Angol cím
Safety requirements for electrical equipment for measurement, control and laboratory use. Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test (IEC 61010-031:2015)
Alkalmazási terület
1.1.1 Probe assemblies included in scope This part of IEC 61010 specifies safety requirements for hand-held and hand-manipulated probe assemblies of the types described below, and their related accessories. These probe assemblies are for direct electrical connection between a part and electrical test and measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment. a) Type A: low-voltage and high-voltage, non-attenuating probe assemblies. Non-attenuating probe assemblies that are RATED for direct connection to voltages exceeding 30 V r.m.s., 42,4 V peak, or 60 V d.c., but not exceeding 63 kV. They do not incorporate components which are intended to provide a voltage divider function or a signal conditioning function, but they may contain non-attenuating components such as fuses (see Figure 1.) b) Type B: high-voltage attenuating or divider probe assemblies. Attenuating or divider probe assemblies that are RATED for direct connection to secondary voltages exceeding 1 kV r.m.s. or 1,5 kV d.c. but not exceeding 63 kV r.m.s. or d.c. The divider function may be carried out wholly within the probe assembly, or partly within the test or measurement equipment to be used with the probe assembly (see Figure 2). c) Type C: low-voltage attenuating or divider probe assemblies. Attenuating or divider probe assemblies for direct connection to voltages not exceeding 1 kV r.m.s. or 1,5 kV d.c. The signal conditioning function may be carried out wholly within the probe assembly, or partly within the test or measurement equipment intended to be used with the probe assembly (see Figure 3). d) Type D: low-voltage attenuating, non-attenuating or other signal conditioning probe assemblies, that are RATED for direct connection only to voltages not exceeding 30 V r.m.s., or 42,4 V peak, or 60 V d.c., and are suitable for currents exceeding 8 A (see Figure 4). Ábrák 1.1.2 Probe assemblies excluded from scope This standard does not apply to current sensors within the scope of IEC 61010-2-032 (Handheld and hand-manipulated current sensors), but may apply to their input measuring circuit leads and accessories. 1.2 Object 1.2.1 Aspects included in scope The purpose of the requirements of this standard is to ensure that HAZARDS to the OPERATOR and the surrounding area are reduced to a tolerable level. Requirements for protection against particular types of HAZARDS are given in Clauses 6 to 13, as follows: a) electric shock or burn (see Clauses 6, 10 and 11); b) mechanical HAZARDS (see Clauses 7, 8 and 11); c) excessive temperature (see Clause 9); d) spread of fire from the probe assembly (see Clause 9); e) arc flash (see Clause 13). Additional requirements for probe assemblies which are designed to be powered from a lowvoltage mains supply, or include other features not specifically addressed in this standard are in other parts of IEC 61010. NOTE Attention is drawn to the possible existence of additional requirements regarding the health and safety of labour forces. 1.2.2 Aspects excluded from scope This standard does not cover: a) reliable function, performance, or other properties of the probe assembly; b) effectiveness of transport packaging. 1.3 Verification This standard also specifies methods of verifying that the probe assembly meets the requirements of this standard, through inspection, TYPE TESTS, and ROUTINE TESTS. 1.4 Environmental conditions 1.4.1 Normal environmental conditions This standard applies to probe assemblies designed to be safe at least under the following conditions: a) altitude up to 2 000 m; b) ambient temperature of 5 °C to 40 °C; c) maximum relative humidity of 80 % for temperatures up to 31 °C decreasing linearly to 50 % relative humidity at 40 °C; d) applicable POLLUTION DEGREE of the intended environment. 1.4.2 Extended environmental conditions This standard applies to probe assemblies designed to be safe not only in the environmental conditions specified in 1.4.1, but also in any of the following conditions as RATED by the manufacturer of the probe assemblies: a) outdoor use; b) altitudes above 2 000 m; c) ambient temperatures below 5 °C or above 40 °C; d) relative humidities above the levels specified in 1.4.1; e) WET LOCATIONS.
ICS
19.080 Villamos és elektronikus vizsgálat
A szabvány nyelve
angol
Az érvényesség kezdete
2015-12-01
A visszavonás napja
2026-03-06
További adatok
Forrás
idt IEC 61010-031:2015; idt EN 61010-031:2015
Kiegészítő információk
SZK-közlemények
Kapcsolódó európai jogszabály
2006/95/EK; (LVD06); 2014/35/EU (LVD14)
Kereskedelmi adatok
A szabvány
kapható formátuma
Papír ,
PDF (letöltés) (a fájl mérete: 2411472) ,
oldalszáma
90 oldal; XB kategória
ára
Nettó: 25750 Ft
Bruttó:
Papír formátum esetén (5% Áfával): 32445 Ft
PDF (letöltés) formátum esetén (27% Áfával): 32703 Ft
Szabvány életútja
Megtekintett szabvány

MSZ EN 61010-031:2015

2015-12-01 - 2026-03-06