Szabványkereső

Hivatkozási szám, azonosító jelzet, vagy a szabványcímben előforduló kulcsszó szerinti keresés:


ICS (a szabványok nemzetközi osztályozási rendszere) szerinti keresés

Nettó ár: 15850 Ft
Kosárba tesz
Alapadatok
Hivatkozási szám
MSZ EN 61010-2-032:2013
Dokumentumazonosító
156779
Cím
Villamos mérő-, szabályozó- és laboratóriumi készülékek biztonsági előírásai. 2-032. rész: Kézben tartott és kézzel működtetett, villamos vizsgálati és mérési célú áramszondák követelményei (IEC 61010-2-032:2012)
Angol cím
Safety requirements for electrical equipment for measurement, control, and laboratory use. Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement (IEC 61010-2-032:2012)
Alkalmazási terület
This clause of Part 1 is applicable except as follows: Equipment included in scope Replacement: Replace the existing text with the following: This part of IEC 61010 specifies safety requirements for HAND-HELD and hand-manipulated current sensors described below. These current sensors are for measuring, detecting or injecting current, or indicating current waveforms on circuits without physically opening the current path of the circuit being measured. They may be stand-alone current sensors or accessories to other equipment or parts of combined equipment (see Figure 101). These include measurement circuits which are part of electrical test and measurement equipment, laboratory equipment, or process control equipment. The existence of these current sensors and circuits in equipment requires additional protective means between the current sensor, the circuit and an OPERATOR. NOTE 1 This part includes also the requirements of Part 2-030. Testing and measuring circuits that are not within the scope of this part are considered to be covered by the requirements of Part 1 or other parts 2s of IEC 61010, and then will also need to meet the requirements of these other parts with the exception of Part 2-030. Current clamp meters and similar currents sensors that have a primary purpose of measuring voltage on a live MAINS CIRCUIT are also within the scope of Part 2-033. NOTE 2 Some current sensors are also known as current clamps and current probes. Current sensors require hand manipulation before or after a test or measurement, but do not necessarily need to be HAND-HELD during the test or measurement. NOTE 3 Some current sensors designed for portable use can also be used for fixed installations. The following types of current sensors are covered: a) Type A: a current sensor designed to be applied around or removed from UNINSULATED HAZARDOUS LIVE conductors. Type A current sensors have defined HAND-HELD or handmanipulated parts providing protection against electric shock from the conductor being measured, and also have protection against short-circuits between wires and busbars during clamping. b) Type B: a current sensor which has protection against short-circuits between wires or busbars during clamping but without defined HAND-HELD or hand-manipulated parts which provide protection against electric shock during clamping. Additional protective means are necessary to avoid electric shock from HAZARDOUS LIVE conductors which cannot be deenergised during application or removal of the current sensor. EXAMPLE 1 Flexible current sensors. c) Type C: a current sensor without protection against short-circuits between wires or busbars during clamping. Type C current sensors are intended to be applied to or removed from UNINSULATED HAZARDOUS LIVE conductors or from non-limited-energy circuit conductors only when they are de-energised. EXAMPLE 2 Split-core transducers. d) Type D: a current sensor designed to be applied around or removed from insulated conductors or from limited-energy circuit conductors. A Type D current sensor does not need protection against short-circuits during clamping and has no defined HAND-HELD or hand-manipulated parts providing protection against electric shock from the conductor being measured. EXAMPLE 3 Current probes for oscilloscopes and earth leakage current detectors. NOTE 4 All current sensors can also be used around insulated conductors. In this case, HAZARDS are limited to acceptable levels by the insulation of the conductors.
ICS
19.080 Villamos és elektronikus vizsgálat
A szabvány nyelve
angol
Az érvényesség kezdete
2013-09-01
A visszavonás napja
2024-11-12
További adatok
Forrás
idt EN 61010-2-032:2012; idt IEC 61010-2-032:2012
Módosítás
Kiegészítő információk
SZK-közlemények
Kapcsolódó európai jogszabály
2006/95/EK; (LVD06); 2014/35/EU (LVD14)
Kereskedelmi adatok
A szabvány
kapható formátuma
Papír ,
PDF (letöltés) (a fájl mérete: 561225) ,
oldalszáma
48 oldal; T kategória
ára
Nettó: 15850 Ft
Bruttó:
Papír formátum esetén (5% Áfával): 19971 Ft
PDF (letöltés) formátum esetén (27% Áfával): 20130 Ft
Szabvány életútja
Megtekintett szabvány

MSZ EN 61010-2-032:2013

2013-09-01 - 2024-11-12