Szabványkereső

Hivatkozási szám, azonosító jelzet, vagy a szabványcímben előforduló kulcsszó szerinti keresés:


ICS (a szabványok nemzetközi osztályozási rendszere) szerinti keresés

Nettó ár: 17420 Ft
Kosárba tesz
Alapadatok
Hivatkozási szám
MSZ EN 1422:1997+A1:2009
Dokumentumazonosító
148102
Cím
Egészségügyi célú sterilizátorok. Etilén-oxid-sterilizátorok. Követelmények és vizsgálati módszerek
Angol cím
Sterilizers for medical purposes. Ethylene oxide sterilizers. Requirements and test methods
Alkalmazási terület
1.1 This European standard specifies the minimum performance requirements and test methods of two types of sterilizers employing ethylene oxide gas as the sterilant, either as a pure gas or in admixture with other gases (whether supplied ready mixed or mixed at the point of use) in a temporarily sealed chamber. These sterilizers are intended to be used for medical, dental, pharmaceutical, veterinary and industrial or related purposes. The two types of sterilizers have been designated Type A and Type B respectively using the following criteria: - Type A sterilizers are capable of being programmed by the user; - Type B sterilizers are of limited size and provided with one or more pre-set operating cycles which cannot be varied by the user. The clauses of this standard apply to both types of sterilizer unless it is specifically indicated within the clause that it applies only to one of the types in particular. 1.2 This standard includes minimum performance and construction requirements for sterilizers working above or below atmospheric pressure: - To ensure that the process is capable of being used to sterilize medical products; - For the equipment and controls necessary to permit validation and monitoring of the sterilization process. 1.3 This standard does not specify those tests which are necessary to determine the probability of a processed product being sterile, nor the routine quality control tests required prior to release of sterile product. These topics are addressed in EN 550. 1.4 This standard does not specify the procedures and equipment which can be used to improve the efficacy and/or efficiency of the process before or after the sterilization cycle. 1.5 Considerations of operator safety are addressed in EN 61010-1: A2 and IEC 1010-2-042. 1.6 This standard is applicable when: a) Specified in a contract for supply of an ethylene oxide sterilizer; or, b) A sterilizer manufacturer declares compliance when intending to supply an ethylene oxide st
ICS
11.080.10 Sterilizálóberendezések
Műszaki Bizottság
A szabvány nyelve
angol
Az érvényesség kezdete
2009-09-01
A visszavonás napja
2014-09-01
További adatok
Forrás
idt EN 1422:1997+A1:2009
Módosítás
SZK-közlemények
Kapcsolódó európai jogszabály
93/42/EGK A TANÁCS 93/42/EGK IRÁNYELVE (1993. június 14.) az orvostechnikai eszközökről (MDV93)
Kereskedelmi adatok
A szabvány
kapható formátuma
Papír ,
PDF (letöltés) (a fájl mérete: 550743) ,
oldalszáma
57 oldal; U kategória
ára
Nettó: 17420 Ft
Bruttó:
Papír formátum esetén (5% Áfával): 21949 Ft
PDF (letöltés) formátum esetén (27% Áfával): 22123 Ft
Szabvány életútja
Elődök
Megtekintett szabvány

MSZ EN 1422:1997+A1:2009

2009-09-01 - 2014-09-01