Szabványkereső

Hivatkozási szám, azonosító jelzet, vagy a szabványcímben előforduló kulcsszó szerinti keresés:


ICS (a szabványok nemzetközi osztályozási rendszere) szerinti keresés

Nettó ár: 29610 Ft
Kosárba tesz
Alapadatok
Hivatkozási szám
MSZ EN IEC 60947-9-2:2025
Dokumentumazonosító
187019
Cím
Kisfeszültségű kapcsoló- és vezérlőkészülékek. 9-2. rész: Átíveléses zárlat elleni, aktív védelmi rendszerek. Optikai alapú belső ívérzékelő és ívelhárító eszközök (IEC 60947-9-2:2021)
Angol cím
Low-voltage switchgear and controlgear. Part 9-2: Active arc-fault mitigation systems. Optical-based internal arc-detection and mitigation devices (IEC 60947-9-2:2021)
Alkalmazási terület
This document covers internal arc-fault control devices, hereinafter referred to as IACD, which are intended to: - detect internal arc-faults in low-voltage switchgear and controlgear assemblies, by processing (at a minimum) the optical effect of an internal arc-fault, and - operate mitigation device (either external or combined) in order to minimize the effects of the internal arc-fault (see Figure 1). For the purpose of this document the terms "light" or "optical" covers more than visible spectra. They may cover also, for example, infrared or ultraviolet electromagnetic radiations (see Annex D). For combined-type IACD, this document is considered in addition to the relevant product standard for internal arc-fault mitigation devices (IARD per IEC TS 63107:2020). Compliance to the relevant product standard is mandatory and cannot be claimed by testing to this document alone. NOTE 1 Low-voltage switchgear and controlgear assemblies are usually described by IEC 61439 series. Figure NOTE This figure displays a simplified IACD schematic with only one optical sensor and no other sensing means that can be used for secondary confirmation of an arcing fault, such as current sensing. Key 1 assembly enclosure 2 internal arc-fault 3 optical sensor 4 processing unit 5 trigger output used to operate e.g. mitigation device Figure 1 - Optical-based IACD schematic (stand-alone type and no secondary sensor) Therefore, this document covers the following: - internal arc-fault control device (stand-alone, multifunction or combined); - one or more associated sensor(s) used to detect optical effect of the internal arc-fault; - sensor(s), sensing another physical effect, to confirm the fault; - associated or combined mitigation device. An IACD is not intended to trigger under normal operation of low-voltage switchgear and controlgear (i.e. absence of internal arc-fault), including normal arcing associated with operation of disconnecting and switching devices. This document only covers the following methods: - optical detection of the light caused by an internal arc-fault; - optional confirmation of internal arc-fault by line current measurement. Many different conductive materials could be used in LV assemblies (e.g. steel, copper, aluminium). Nevertheless, tests specified in this document are deemed to represent the most critical and challenging conditions for arc-detection and cover all combinations of conductive materials. NOTE 2 Compared to other materials (e.g. steel, aluminium), copper leads to a lower optical radiation energy. The rated voltage of the assembly in which an IACD is installed does not exceed 1 000 V AC. Such devices are designed to be operated and maintained by skilled persons only. This document does not cover: - DC internal arc-fault detection and control; - overcurrent relays; - AFDD (arc-fault detection devices) as defined by IEC 62606; - guidance on installation within assemblies; NOTE 3 The integration of an IACD into an assembly is described in IEC TS 63107. - use with additional measures needed for installation and operation within explosive atmospheres. These are given in IEC 60079 series documents; - requirements for embedded software and firmware design rules; for this subject, the manufacturer is responsible for taking additional safety measures; NOTE 4 IEC TR 63201 describes rules for firmware and embedded software development preventing errors in software. - cybersecurity aspects; for this subject, the manufacturer is responsible for taking additional safety measures; NOTE 5 See IEC TS 63208. - mobile applications. NOTE 6 Even when addressing internal arc-fault mitigation devices, this document does not supersede any other relevant product standard (e.g. IEC 60947-2 or IEC 60947-9-1). NOTE 7 DC arcing fault phenomena are under consideration. Further investigation is needed to comprehend DC arcing phenomena and required sensing.
ICS
29.120.40 Kapcsolók
29.130.20 Kisfeszültségű kapcsoló- és vezérlőberendezések
A szabvány nyelve
angol
Az érvényesség kezdete
2025-12-01
További adatok
Forrás
idt IEC 60947-9-2:2021; idt EN IEC 60947-9-2:2025
Előd
Utód
Módosítás
Kiegészítő információk
SZK-közlemények
Kapcsolódó európai jogszabály
2014/35/EU (LVD14); 2014/30/EU (EMC14)
Kereskedelmi adatok
A szabvány
kapható formátuma
Papír ,
PDF (letöltés) (a fájl mérete: 4206577) ,
oldalszáma
91 oldal; XB kategória
ára
Nettó: 29610 Ft
Bruttó:
Papír formátum esetén (20% nyomdai költséggel, 5% Áfával): 37309 Ft
PDF (letöltés) formátum esetén ( 27% Áfával): 37605 Ft
Szabvány életútja
Elődök

Jelenleg nincsenek előzmények

Megtekintett szabvány

MSZ EN IEC 60947-9-2:2025

2025-12-01

Utódok

Jelenleg nincsenek utódok