Szabványkereső

Hivatkozási szám, azonosító jelzet, vagy a szabványcímben előforduló kulcsszó szerinti keresés:


ICS (a szabványok nemzetközi osztályozási rendszere) szerinti keresés

Nettó ár: 12520 Ft
Kosárba tesz
Alapadatok
Hivatkozási szám
MSZ EN IEC 60034-30-3:2024
Dokumentumazonosító
184233
Cím
Villamos forgógépek. 30-3. rész: Nagyfeszültségű váltakozó áramú motorok hatásfok szerinti osztályai (IE-kód) (IEC 60034-30-3:2024)
Angol cím
Rotating electrical machines. Part 30-3: Efficiency classes of high voltage AC motors (IE-code) (IEC 60034-30-3:2024)
Alkalmazási terület
This part of IEC 60034 specifies efficiency classes for fixed-speed three-phase high-voltage cage induction motors in accordance with IEC 60034-1 that • have a rated voltage exceeding 1 000 V, but not exceeding 11 kV; • have a rated power from 200 kW to 2 000 kW; NOTE 1 Motors with rated power above 2 000 kW are produced in such small numbers and are designed and produced with a focus on achieving an optimum efficiency anyway, even though fulfilling increasingly special requirements that assigning efficiency classes would be an additional effort without the result of any countable energy saving. • have two, four or six poles; • are rated for single-speed line-operation; • are intended for direct-on-line starting at rated or at reduced voltage and rated frequency; • are constructed to any degree of protection; • are designed for cooling methods IC411, IC511, IC611, IC01 or IC81W; • are capable of continuous operation at their rated operating point (torque/power, speed) with a temperature rise within the specified insulation temperature class; NOTE 2 Most motors covered by this document are rated for duty type S1 (continuous duty). However, some motors that are rated for other duty cycles are still capable of continuous operation at their rated power and these motors are also covered. • are rated for any ambient temperature or coolant temperature within the range of – 20 °C to + 60 °C; NOTE 3 Motors rated for temperatures outside the range – 20 °C and + 60 °C are considered to be of special construction and are consequently excluded from this document. • are rated for an operating altitude up to 2 000 m above sea level; NOTE 4 The rated efficiency and the efficiency class are based on a rating for altitudes up to 1 000 m above sea level. • have a locked-rotor current Il at stand-still and supply with rated voltage and frequency before application of any IEC or agreed tolerance in the range Il / IN ? 4,5; • are designed for a customer load torque during starting not exceeding an envelope with a minimum of 25 % of the rated torque at low speed and a square shape T ~ n2 up to a maximum load torque at full speed of 60 % of the rated torque in case of 2 pole motors or 100 % of the rated torque in case of 4 pole or 6 pole motors, respectively, (see Figure 1), After starting is completed, the load torque of 2 pole motors is increased to 100 % of the rated torque; • have to accelerate an external moment of inertia as defined by the customer requirements not exceeding the values given in Table 1 considering all start up conditions defined in this document for not more than three consecutive starts from cold condition or two starts from hot condition, respectively; • are designed for a minimum locked-rotor steady state supply voltage of at least 80 % of the rated voltage during starting. Figure 1 – Envelope of the load torque during starting: Load torque during starting in % of rated torque over speed in % of rated speed Table 1 – Maximum external moment of inertia Excluded are: • Motors with mechanical commutators or slip-rings; • Motors with 8 or more poles; • Multi-speed motors; • Motors with customer starting torque requirements exceeding the load torque envelope above, and motors exceeding the maximum external inertia defined in Table 1; • Motors designed specifically for operation fed by a power electronic frequency converter with a temperature rise within the specified insulation thermal class or thermal class; • Motors completely integrated with the driven machine (for example pumps, fans and compressors). This means that the motor cannot be designed in such a way as to enable the motor to be separated from the driven unit, i.e. it is not possible to operate the separated motor without the driven unit; • Submersible motors specifically designed to operate wholly immersed in a liquid; • Smoke extraction motors; • Motors dedicated to operate in explosive atmospheres; • Motors for operation in nuclear plants, especially nuclear power plants.
ICS
29.160.01 Forgógépek általában
29.160.10 Forgógépalkatrészek
29.160.30 Motorok
A szabvány nyelve
angol
Az érvényesség kezdete
2024-08-01
További adatok
Forrás
idt EN IEC 60034-30-3:2024; idt IEC 60034-30-3:2024
Előd
Utód
Módosítás
Kiegészítő információk
SZK-közlemények
Kapcsolódó európai jogszabály
Kereskedelmi adatok
A szabvány
kapható formátuma
Papír ,
PDF (letöltés) (a fájl mérete: 1417002) ,
oldalszáma
26 oldal; P kategória
ára
Nettó: 12520 Ft
Bruttó:
Papír formátum esetén (5% Áfával): 15775 Ft
PDF (letöltés) formátum esetén (27% Áfával): 15900 Ft
Szabvány életútja
Elődök

Jelenleg nincsenek előzmények

Megtekintett szabvány

MSZ EN IEC 60034-30-3:2024

2024-08-01

Utódok

Jelenleg nincsenek utódok