Szabványkereső

Hivatkozási szám, azonosító jelzet, vagy a szabványcímben előforduló kulcsszó szerinti keresés:


ICS (a szabványok nemzetközi osztályozási rendszere) szerinti keresés

Nettó ár: 11980 Ft
Kosárba tesz
Alapadatok
Hivatkozási szám
MSZ EN ISO 19581:2020
Dokumentumazonosító
175454
Cím
A radioaktivitás mérése. Gamma-sugárzó radionuklidok. Gyors szűrési módszer szcintillációs detektorú gamma-spektrometriával (ISO 19581:2017)
Angol cím
Measurement of radioactivity. Gamma emitting radionuclides. Rapid screening method using scintillation detector gamma-ray spectrometry (ISO 19581:2017)
Alkalmazási terület
This document specifies a screening test method to quantify rapidly the activity concentration of gamma-emitting radionuclides, such as ^131ˇI, ^132ˇTe, ^134ˇCs and ^137ˇCs, in solid or liquid test samples using gamma-ray spectrometry with lower resolution scintillation detectors as compared with the HPGe detectors (see IEC 61563). This test method can be used for the measurement of any potentially contaminated environmental matrices (including soil), food and feed samples as well as industrial materials or products that have been properly conditioned. Sample preparation techniques used in the screening method are not specified in this document, since special sample preparation techniques other than simple machining (cutting, grinding, etc.) should not be required. Although the sampling procedure is of utmost importance in the case of the measurement of radioactivity in samples, it is out of scope of this document; other international standards for sampling procedures that can be used in combination with this document are available (see References [1],[2],[3],[4],[5],[6]). The test method applies to the measurement of gamma-emitting radionuclides such as ^131ˇI, ^134ˇCs and ^137ˇCs. Using sample sizes of 0,5 l to 1,0 l in a Marinelli beaker and a counting time of 5 min to 20 min, decision threshold of 10 Bq·kg^-1ˇ can be achievable using a commercially available scintillation spectrometer [e.g. thallium activated sodium iodine (NaI(Tl)) spectrometer 2” Fí × 2” detector size, 7 % resolution (FWHM) at 662 keV, 30 mm lead shield thickness]. This test method also can be performed in a “makeshift” laboratory or even outside a testing laboratory on samples directly measured in the field where they were collected. During a nuclear or radiological emergency, this test method enables a rapid measurement of the sample activity concentration of potentially contaminated samples to check against operational intervention levels (OILs) set up by decision makers that would trigger a predetermined emergency response to reduce existing radiation risks^[12]ˇ. Due to the uncertainty associated with the results obtained with this test method, test samples requiring more accurate test results can be measured using high-purity germanium (HPGe) detectors gamma-ray spectrometry in a testing laboratory, following appropriate preparation of the test samples^[7][8]ˇ. This document does not contain criteria to establish the activity concentration of OILs.
ICS
17.240 Sugárzásmérések
A szabvány nyelve
angol
Az érvényesség kezdete
2020-08-01
További adatok
Forrás
idt EN ISO 19581:2020; idt ISO 19581:2017
Előd
Utód
Módosítás
Kiegészítő információk
SZK-közlemények
Kapcsolódó európai jogszabály
Kereskedelmi adatok
A szabvány
kapható formátuma
Papír ,
PDF (letöltés) (a fájl mérete: 1328695) ,
oldalszáma
27 oldal; N kategória
ára
Nettó: 11980 Ft
Bruttó:
Papír formátum esetén (5% Áfával): 15095 Ft
PDF (letöltés) formátum esetén (27% Áfával): 15215 Ft
Szabvány életútja
Elődök

Jelenleg nincsenek előzmények

Megtekintett szabvány

MSZ EN ISO 19581:2020

2020-08-01

Utódok

Jelenleg nincsenek utódok