Szabványkereső

Hivatkozási szám, azonosító jelzet, vagy a szabványcímben előforduló kulcsszó szerinti keresés:


ICS (a szabványok nemzetközi osztályozási rendszere) szerinti keresés

Nettó ár: 19470 Ft
Kosárba tesz
Alapadatok
Hivatkozási szám
MSZ EN 60909-0:2001
Dokumentumazonosító
116877
Cím
Zárlati áramok háromfázisú váltakozó áramú rendszerekben. 0. rész: Az áramok számítása (IEC 60909-0:2001)
Angol cím
Short-circuit current in three-phase a.c. systems. Part 0: Calculation of currents (IEC 60909-0:2001)
Alkalmazási terület
This part of IEC 60909 is applicable to the calculation of short-circuit currents: ? in low-voltage three-phase a.c. systems ? in high-voltage three-phase a.c. systems operating at a nominal frequency of 50 Hz or 60 Hz. Systems at highest voltages of 550 kV and above with long transmission lines need special consideration. This part of IEC 60909 establishes a general, practicable and concise procedure leading to results, which are generally of acceptable accuracy. For this calculation method, an equivalent voltage source at the short-circuit location is introduced. This does not exclude the use of special methods, for example the superposition method, adjusted to particular circumstances, if they give at least the same precision. The superposition method gives the short-circuit current related to the one load flow presupposed. This method, therefore, does not necessarily lead to the maximum short-circuit current. This part of IEC 60909 deals with the calculation of short-circuit currents in the case of balanced or unbalanced short circuits. In case of an accidental or intentional conductive path between one line conductor and local earth, the following two cases must be clearly distinguished with regard to their different physical properties and effects (resulting in different requirements for their calculation): line-to-earth short circuit, occurring in a solidly earthed neutral system or an impedance earthed neutral system; ? a single line-to-earth fault, occurring in an isolated neutral earthed system or a resonance earthed neutral system. This fault is beyond the scope of, and is therefore not dealt with in, this standard. For currents during two separate simultaneous single-phase line-to-earth short circuits in an isolated neutral system or a resonance earthed neutral system, see IEC 60909-3. Short-circuit currents and short-circuit impedances may also be determined by system tests, by measurement on a network analyzer, or with a digital computer. In existing low-voltage systems it is possible to determine the short-circuit impedance on the basis of measurements at the location of the prospective short circuit considered.
ICS
17.220.01 Villamosság. Mágnesség. Általános szempontok
Műszaki Bizottság
A szabvány nyelve
angol
Az érvényesség kezdete
2001-12-01
A visszavonás napja
2019-06-10
További adatok
Forrás
idt EN 60909-0:2001; idt IEC 60909-0:2001
Módosítás
SZK-közlemények
Kapcsolódó európai jogszabály
Kereskedelmi adatok
A szabvány
kapható formátuma
Papír ,
PDF (letöltés) (a fájl mérete: 984809) ,
oldalszáma
73 oldal; W kategória
ára
Nettó: 19470 Ft
Bruttó:
Papír formátum esetén (5% Áfával): 24532 Ft
PDF (letöltés) formátum esetén (27% Áfával): 24727 Ft
Szabvány életútja
Megtekintett szabvány

MSZ EN 60909-0:2001

2001-12-01 - 2019-06-10