MSZ EN 60601-2-20:2010

Gyógyászati villamos készülékek. 2-20. rész: Csecsemőszállító inkubátorok alapvető biztonsági és lényeges teljesítőképességi követelményei (IEC 60601-2-20:2009)

Medical electrical equipment. Part 2-20: Particular requirements for the basic safety and essential performance of infant transport incubators (IEC 60601-2-20:2009)


Clause 1 of the general standard applies, except as follows: 201.1.1 Scope Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT TRANSPORT INCUBATOR equipment, as defined in 201.3.211 of this standard, also referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. NOTE See also 4.2 of the general standard. This particular standard specifies safety requirements for INFANT TRANSPORT INCUBATORS but alternate methods of compliance with a specific clause by demonstrating equivalent safety will not be judged as non compliant if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device. This particular standard does not apply to: – devices supplying heat via BLANKETS, PADS or MATTRESSES in medical use; for information see IEC 80601-2-35 [1]1); – INFANT INCUBATORS which are not INFANT TRANSPORT INCUBATOR; for information see IEC 60601-2-19 [2]; – INFANT RADIANT WARMERS; for information, see IEC 60601-2-21 [3]; – INFANT PHOTOTHERAPY; for information, see IEC 60601-2-50 [4]. 201.1.2 Object Replacement: The object of this particular standard is to establish particular BASIC SAFETY and ESSENTIAL PERFORMANCE requirements for INFANT TRANSPORT INCUBATORS as defined in 201.3.211, which minimize HAZARDS to the PATIENT and OPERATOR, and to specify tests by which compliance with the requirements can be verified. 201.1.3 *Collateral standards Addition: This particular standard refers to those applicable collateral standards that are listed in Clause 2 of the general standard and Clause 2 of this particular standard. IEC 60601-1-2 and IEC 60601-1-10 apply as modified in Clauses 202 and 210 respectively. IEC 60601-1-3 does not apply. All other published collateral standards in the IEC 60601-1 series apply as published. Túl hosszú

Általános információk

Érvényes
angol
: 2010-04-01

11.040.10 - Érzéstelenítő-, lélegeztető és újraélesztő berendezések

MSZT/MB 843  Gyógyászati villamos készülékek

: idt IEC 60601-2-20:2009; idt EN 60601-2-20:2009

: MSZ EN 60601-2-20:2009/A1:2017; MSZ EN 60601-2-20:2009/A11:2012

Vásárlás

: 11 390,0 Ft
(papír , PDF-fájl-letöltés)



Szabvány életútja

Előzmények
Megtekintett szabvány
MSZ EN 60601-2-20:2010

2010-04-01

Utódok

Jelenleg nincsenek utódok